Follow

Unable To Create Temp Environment! Error On Logoff

Product: ProfileUnity-FlexApp

Product Version: Observed on 6.5

Expires on: 365 days from publish date

Updated: July 10, 2015

 

Problem:

When logging out of a VM that has the ProfileUnity GPOs applied to it, the machine never finishes the logoff process. No logs are generated. When logging into the VM via console, the following error appears:

 

unable_to_create_temp_environment.PNG

 

Possible Resolution(s):

Please check for duplicate:

LwL.ProfileUnity.Client.Logoff.exe in the GPO of the machine which is receiving this problem.  

 

This could be caused by local GP with global GPO. OR

This occurs when the ProfileUnity user and computer are in the same Active Directory OU and the ProfileUnity Group Policy is applied to that OU. User Group Policy loopback processing mode is enabled on that policy during a default deployment. See this Microsoft article for more information on loopback processing.

The solution is to move the users and computers into separate OUs, linking the ProfileUnity Group Policy to the new OU, or to disable Loopback Processing (Computer Configuration\Administrative Templates\System\Group Policy). 

Was this article helpful?
0 out of 0 found this helpful
Have more questions? Submit a request

0 Comments

Article is closed for comments.