Follow

ProfileUnity logoff is terminated early on VDI-in-a-Box system

Product: ProfileUnity-FlexApp

Product Version: 6.x

Expires on: 365 days from publish date

Updated: June 20, 2016

 

Problem:

ProfileUnity's logoff is terminated early on Citrix VDI-in-a-Box is

 

Symptoms:

Debug logoff logs are cut off.

 

Possible Resolution(s):

1) Disable quick shutdown on VDI-in-a-Box system

2) Enable shutdown by ProfileUnity client:

Edit:
LwL.ProfileUnity.Client.Logoff.exe.config
located in  ...netlogon\profileunity directory

Find this line:
</setting>
      <setting name="Shutdown" serializeAs="String">
        <value>False</value> 

Than change the value from "False" to "True.

Save.

 

Now shutdown will be initiated by ProfileUnity. 

Was this article helpful?
0 out of 0 found this helpful
Have more questions? Submit a request

0 Comments